Max Input PV Voc 150VDC 60A 3000W 12V 48V MPPT Solar Charge Controller

Minimum Order Quantity : 5 Packaging Details : Carton, export type packing or according to your requirement
Delivery Time : According to your order quantity or your requirement Payment Terms : L/C, T/T
Supply Ability : 500
Place of Origin: China Nama merek: SOROTEC
Sertifikasi: CE,ROHS,ISO9000 Model Number: MPPT Solar Charge Controller

Informasi Detail

MPPT Range @Operating Voltage: 60 ~115VDC Maximum PV Array Open Circuit Voltage: 145VDC
Size(L*W*H): 315 x 165 x 128mm weight(kg): N.W:4.5KG
colour: blue,green,black,red Type of Mechanical Protection: IP 31
Humidity: 0 ~ 100% RH (No condensing) Operating Temperature: -20°C to 55°C
Storage Temperature: -40°C to 75°C
Cahaya Tinggi:

mppt solar regulator

,

Solar Charger Controller

Deskripsi Produk

Max Input PV Voc 150VDC 60A 3000W 12V 48V MPPT Solar Charge Controller

 

 

 

Key Features:

1. Max.3000W Output

2. Compatible for PV systems in 12v, 24v or 48v

3. Three-stage charging optimizes battery performance

4. Maximum charging current up to 60a

5. Maximum efficiency up to 98%

6. Battery temperature sensor (BTS) automatically provides temperature compensation

7. Support wide range of lead-acid batteries including wet, AGM, and gel batteries

8. Multi-function LCD displays detailed information

 

 

 

Application

Solar charge controller is mainly used for solar power station, home solar power system, solar street light control system, mobile solar power system, DC wind solar generating systems.

 

 

 

 
                                                     PRODUCT SHOW

 

Max Input PV Voc 150VDC 60A 3000W 12V 48V MPPT Solar Charge Controller 0

Product Descriptions of Mppt Solar Charge Controller

Modle Solar Charge Controller
INPUT
MPPT Range @Operating Voltage 60 ~115VDC
Maximum PV Array Open Circuit Voltage 145VDC
Maximum PV Array Power 800W 1600W 3200W
Maximum Input Current 50A
OUTPUT
Nominal Battery Voltage 12VDC 24VDC 48VDC
Connected Battery Type Sealed lead acid, AGM or Gel
Maximum Charge Current 60A
Maximum Efficiency 98%
Charging Method Three stages: bulk, absorption and floating
PROTECTION
Overload Protection > 110% : audible alarm
Overcharge Protection Yes
Polarity Reversal Protection @ Solar Cell & Battery  
Yes
INDICATORS
LCD Panel LCD panel indicating solar power, load level, battery voltage/capacity, charging current, and fault conditions
LED Display Three indicators for solar, charging, and load status
PHYSICAL
Dimension, D x W x H (mm) 315 x 165 x 128
Net Weight (kgs) 4.5
Type of Mechanical Protection IP 31
ENVIRONMENT
Humidity 0 ~ 100% RH (No condensing)
Operating Temperature -20°C to 55°C
Storage Temperature -40°C to 75°C
Altitude 0 ~ 3000 m
 
 
 
 
            APPLICATION OF OUR PRODUCT

1. Living house and home building

2. Office building, factory and warehouse

3. Shopping mall, stadium and so on

4. Power station, field operation and some huge engineer construction

5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip

 

 

 
                             COMPANY SHOW

Introduction of Company

Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.

 

 

 
                             WHY CHOOSE US ?

 

1,QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.

 

2,Best Partner

We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.

 

 

 
                                        FAQ

 

1.How to choose suitable inverter?

 

If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.

 

For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.

 

Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.

 

.......................................................................................................................................................................................................................................

 

2.How do I choose the size of the inverter?

 

Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.

 

Notice:

 

Resistive load: you can choose the same power as the load.

 

Capacitive loads: according to the load, you can choose 2-5 times power.

 

Inductive loads: according to the load, you can choose 4-7 times power.

 

........................................................................................................................................................................................................................................

 

3.How connection between batteries and an power inverter?

 

We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.

 

.....................................................................................................................................................................................................................................

 

4.How to calculate the load of working hours requires configuration of the battery size?

 

We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:

 

Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

 

.......................................................................................................................................................................................................................................

 

 